Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add filters








Language
Year range
1.
Chinese Journal of Nosocomiology ; (24)2006.
Article in Chinese | WPRIM | ID: wpr-590404

ABSTRACT

OBJECTIVE To find out the situation of the application of anti-bacterial drugs in liver transplantation perioperative patients and to improve the quality of their usage.METHODS According to the criteria of DDD and DUI recommended by WHO,making a random sampling survey of the application of anti-bacterials in 206 liver transplantation perioperative patients who discharged hospital during Jan-Dec 2006,and then to analyze the rationality of their application.RESULTS Among the 206 patients,100.0% patients had received anti-bacterial drugs involving 13 kinds,137 patients in them used one,31.1% used two and 2.4% used three,and there were twelve in thirteen kinds of drugs whose DUI was no more than one.CONCLUSIONS The survey has proved that the liver transplantation perioperative patients have received rational therapy.

2.
Chinese Journal of Nosocomiology ; (24)2004.
Article in Chinese | WPRIM | ID: wpr-592791

ABSTRACT

OBJECTIVE To study the interaction of anthracene quinone type anti-tumor antibiotics and DNA as well as the experiment method.METHODS Spectrophotometry was developed including absorption spectrum,fluorescence spectrum,electrochemical method and so on.RESULTS The union of inlay and insertion observed in ultraviolet and visible spectrophotometry usually caused hypochromic effect and red shift.Under the certain concentrations of bovin serum albumin(BSA),the endogene fluorescence intensity of BSA orderly reduced with the increase in concentration of doxorubicin(adriamycin) hydrochloride(?em 344 and the peak shape were invariable);?ex and ?em at the biggest wave length of doxorubicin were 478 and 596 nm.The fluorescence intensity was maximal of the excitation and emission spectrum when pH was 3.0.CONCLUSIONS The interaction of doxorubicin and DNA is the strongest according to the experiment and is the most widely used at present in clinics.

3.
Chinese Journal of Nosocomiology ; (24)2004.
Article in Chinese | WPRIM | ID: wpr-587541

ABSTRACT

OBJECTIVE To discuss the sterilizing effect of waste gas discharged from hospital central vacuum aspiration system. METHODS According to the characters that direct discharging these waste gases from the central vacuum aspiration system would pollute surrounding environment and that there could not be choke in the venting part of vacuum pump of this system,the method of nanometric photocatalysis was adopted to sterilize the waste gases. RESULTS The average number of colony in the engine room was 2473.67?98.23CFU/m~3 before sterilization.After 1h and 2h of sterilizing,there were 88?17.6 CFU/m~3 and 58.76 ?12.34 CFU/m~3,respectively,with significant difference. CONCLUSIONS It is effective to use the method of nanometric photocatalysis sterilizing the waste gases from the hospital central vacuum aspiration system.The rate of the sterilization is 99.99%.

4.
Chinese Journal of Nosocomiology ; (24)2004.
Article in Chinese | WPRIM | ID: wpr-587535

ABSTRACT

OBJECTIVE To investigate the method of quality control on the whole process in sterilization supply department. METHODS According to issued by Ministry of Health all kinds of criteria and inspections,the whole process in sterilization supply department was analyzed,and then the quality was controlled. RESULTS The whole process of sterilization was standardized,systematized and programmed. CONCLUSIONS The quality control on the whole process is an effective measure to ensure the rate of supply eligibility and support.

5.
Chinese Journal of Nosocomiology ; (24)1994.
Article in Chinese | WPRIM | ID: wpr-585696

ABSTRACT

OBJECTIVE To establish the quality control system of aseptic materials in sterilization and supply department. METHODS According to Antisepsis Technic Criterion,Criterion of Check and Accept of Sterilization and Supply Department in Hospital,and Criterion of Hospital Infection newly issued by National Ministry of Health,to provide quality control of aseptic meterials in hospital. RESULTS The aseptic materials of quality control were improved,and come to being systematic standardized. CONCLUSIONS The improved quality control is an important measure for the guarantee of quality control of aseptic materials.

6.
Chinese Journal of Nosocomiology ; (24)1994.
Article in Chinese | WPRIM | ID: wpr-588818

ABSTRACT

OBJECTIVE To analyze the relationship between the ventilator tube system and VAP.METHODS To investigate the way to use the ventilator tube system more reasonably.RESULTS To replace the ventilator tube every seven days could prevent the VAP effectively and decrease the mechanical ventilation patient′s mortality.CONCLUSIONS Decreasing the VAP incidence is a systematic and integrative work.To reinforce the management of the ventilator tube system is one of the effective methods in preventing VAP.

7.
Chinese Journal of Nosocomiology ; (24)1994.
Article in Chinese | WPRIM | ID: wpr-588809

ABSTRACT

OBJECTIVE To establish communication and cooperation between disinfection and supply department and clinical departments in order to attain the high level of work for sterile material management and quality supervision.METHODS From Jan 2004 to Sept 2006 we sent our color printed pages about disinfection and sterilization knowledge,whole-way quality supervision,management and safety usage of sterile material to each clinical department as a manner of communication.RESULTS The communication gave a harmony of demand and supply of sterile material between them and guaranteed the whole-way superior service for sterile material supply.CONCLUSIONS The communication with whole-way quality management of sterial material supply between the disinfection and supply department and other clinical departments is very important.

SELECTION OF CITATIONS
SEARCH DETAIL